Panasonic Digital Business System - Operating Instructions
March 1997 Issue 24
93
CPC-EX Call Logging
A number of chnages to the call logging output were made with the introduction of the CPC-EX. These are
outlined below. The field layout is the same as for previous versions, but the data options have been expanded.
NNNN--LL--DD--MM--HH:NN--h:mm.ss-C-YYYYYYYYYYYYYYYYYYYYYYYY-AAAAAAAAAA--000.00
NNNN nnnn = Extension Number
Conn = Exchange Line (01-48) used when operating trunk to trunk
Nonn = Private Circuit (01-12) used when breaking out from a private circuit
LL 01-48 = Exchange Line / Channel Number
A = Attendant Performed An Alarm Operation For Indicated Extension
E = Indicated Extension Performed An Alarm Operation
DD MM HH:NN = Day, Month and Time of the call
h:mm:ss = Duration Of The Call
C I = Incoming Analogue Line Call
i = Incoming ISDN Call
O = Outgoing Analouge Line Call
o = Outgoing ISDN Call
Z = Incoming ISDN DDI Call
H = Call Placed On Hold
T = Call Tranferred Or Retrieved From Hold
F = Call Externally Call Forwarded
V = Operator Override Trunk To Trunk Connection/ Operator Trunk To Trunk Conference
L = Incoming Call Which Rang Off Before Being Answered
B = All Lines Busy - Duration Shows How Long All Lines Were Busy
S = Alarm Set
A = Alarm Answered
N = Alarm Not Answered
C = Alarm Cancelled
yyyyyyyyyyyyyyyyyyyyyyyy
yy .. yy = Dialled Number
yy .. yyA = ISDN Dialled Number Answered
Byy .. yy = Number returned from ISDN as TLI is shown
yy .. yyAyyyyy = ISDN Dialled Number Answered With Following DTMF Diallng
NNNNEyy .. yy = Extension NNNN External Forward To Number
mm'ss = Ring Time In Minutes And Seconds
a.ayy .. yy = Number Dialled Via Indirect Carrier With Access Code a.a
x dd .. dd = DDI Number Received To Direct Call To Answer Point
These indications can be combined in most combinations to a maximum field width of 24
AAAAAAAAAA = Account Code / DISA ID used for breakout
PPP.PP = Call Cost Derived From Meter Pulses Or ISDN Call Charge Data