Combined Graph Of A and B Wire Voltages
Field measurements show that the voltage on cleardown is not constant. But rises exponentially towards the ‘talking’ levels
probably due to the exchange line impedance characteristics. Provided the A and B legs follow the same path there will be no
current flow ( as there is no potential difference between the wires ) and CPC should still function. If there is a difference
between the A and B legs then there will be current flow and hence unreliable or inoperative CPC. In such a case the problem
is network related and not a system fault. The following graphs, based on the previous examples show these situations.
Exponential Rise Equal On A And B - CPC Should Be OK