47 EN
English
(measurement: mm)
Minimum 30
for flat part
490
Min. 40
Min. 20
+ 3
- 0
Rear sideFront side
Flow of intake and exhaust
When Installing a Partition Inside the Cabinet
Allow for a minimum of 20 mm extra space underneath the bottom of the
appliance for air circulation.
Allow for a minimum of 40 mm extra space in rear of the partition.
Top view of the partition
Min. 20
Min. 40
70
265
490
560
Partition
Building rear wall
Countertop cutout
Partition
Countertop front
Dimensions
Side View
Caution
If this condition is not met,
do not install the appliance.