Panasonic CSYE12MKX Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Climatiseurs à système divisé Panasonic CSYE12MKX. Panasonic CSYE12MKX Operating Instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 47
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
© Panasonic Home Appliances Air-Conditioning
(Guangzhou) Co.,Ltd (PHAAG) 2010. All rights
reserved. Unauthorized copying and distribution is a
violation of law.
Order No: PHA-AG1102005C2
Indoor Unit Outdoor Unit
CS-YE9MKX
CS-YE12MKX
CS-YE18MKX
CU-YE9MKX
CU-YE12MKX
CU-YE18MKX
TABLE OF CONTENTS
1. Safety Precautions.............................................3
2. Specification.......................................................5
3. Features ..............................................................9
4. Location of Controls and Components .........10
4.1 Indoor Unit .................................................10
4.2 Outdoor Unit...............................................10
4.3 Remote Control ..........................................10
5. Dimensions.......................................................11
5.1 Indoor Unit..................................................11
5.2 Outdoor Unit...............................................12
6. Refrigeration Cycle Diagram...........................13
7. Block Diagram ..................................................14
8. Wiring Diagram.................................................15
9. Printed Circuit Board.......................................19
9.1 Indoor Unit..................................................19
9.2 Outdoor Unit...............................................19
10. Installation Instruction.....................................20
10.1 Select the Best Location ............................20
10.2 Indoor Unit..................................................21
10.3 Outdoor Unit...............................................23
11. Service Mode ....................................................26
11.1 Auto OFF/ON Button..................................26
11.2 Select Remote Control Transmission Code
26
11.3 Operate and Display of Remote Control....27
12. Operation Control.............................................29
12.1 Basic Function............................................29
12.2 Indoor Fan Motor Operation.......................30
12.3 Outdoor Fan Motor Operation....................30
13. Protection control ............................................33
13.1 Protection Control For All Operations ........33
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the products dealt with in this service information by anyone else could result in serious injury or death.
WARNING
Vue de la page 0
1 2 3 4 5 6 ... 46 47

Résumé du contenu

Page 1 - Order No: PHA-AG1102005C2

© Panasonic Home Appliances Air-Conditioning (Guangzhou) Co.,Ltd (PHAAG) 2010. All rights reserved. Unauthorized copying and distribution is a violati

Page 2

10 4. Location of Controls and Components 4.1 Indoor Unit 4.2 Outdoor Unit 4.3 Remote Control z For normal operation, the ERROR RESET

Page 3 - 1. Safety Precautions

11 5. Dimensions 5.1 Indoor Unit 121 49 Unit:mm

Page 4 - CAUTION

12 5.2 Outdoor Unit Unit: mm

Page 5 - 2. Specification

13 6. Refrigeration Cycle Diagram CS/CU-YE9MKX, CS/CU- YE12MKX CS/CU-YE18MKX COOLING HEATING

Page 6

14 7. Block Diagram CS/CU-YE18MKX CS/CU-YE9/12MKX

Page 7

15 8. Wiring Diagram CS-YE9MKX, CS-YE12MKX

Page 8

16 CU-YE9MKX CU-YE12MKX

Page 11 - 5. Dimensions

19 9. Printed Circuit Board 9.1 Indoor Unit 9.2 Outdoor Unit IC104 LED3 LED2 CN-STM3 CN-THSW HACN-FBIC1 X1IC103 IC2 IC

Page 12 - 5.2 Outdoor Unit

2 13.2 Protection Control For Cooling and Soft Dry Operation...35 13.3 Indoor Piping Air

Page 13 - CS/CU-YE18MKX

20 10. Installation Instruction 10.1 Select the Best Location 10.1.1 Indoor Unit • There should not be any heat source or steam near the unit. • T

Page 14 - 7. Block Diagram

21 WallIndoor Outdoor15 mmSleeve fortube ass’yApprox. 5 - 7 mmBushing for tube ass’yPutty or caulking compoundØ 70 through hole10.2 Indoor Unit 10.2.1

Page 15 - 8. Wiring Diagram

22 10.2.3 Indoor Unit Installation

Page 16

23 10.2.4 Connect the Cable to the Indoor Unit 1 The inside and outside connecting cable can be connected without removing the front grille. 2 Con

Page 17

24 tucoT.1ehtfoecafruslanretnieht,deralfylreporpnehW.ssenkcihtnevefoebdnaenihsylnevelliweralfehthtiwtcatnocotnisemoctraperalfehtecniS.hsiniferalfehtkc

Page 18 - CU-YE18MKX

25 10.3.4 Connect the cable to the Outdoor Unit 1 Remove the control board cover from the unit by loosening the screw. 2 Connecting cable between i

Page 19 - 9. Printed Circuit Board

26 11. Service Mode 11.1 Auto OFF/ON Button 1. AUTO OPERATION MODE Once the Auto OFF/ON button is slightly pressed, the unit will immedi

Page 20 - 10. Installation Instruction

27 11.3 Operate and Display of Remote Control 11.3.1 Original setting 11.3.2 Mode selecting button AUTO, HEAT, COOL, DRY can be selected by pressi

Page 21 - 10.2 Indoor Unit

28 11.3.7 Timer setting button There are 4 types of timer setting by pressing Timer setting button: ON-TIMER, OFF-TIMER, ON-OFF TIMER, OFF-ON TIMER.

Page 22

29 12. Operation Control 12.1 Basic Function 12.1.1 Internal Setting Temperature Once the operation starts, remote control setting temperature will b

Page 23 - 10.3 Outdoor Unit

3 CAUTION WARNING WARNING 1. Safety Precautions • Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. • Electrical work

Page 24 - Over 5mm

30 2nd & following judgment (every 15 minutes after 1st judgment) JUDGE CONDITION REFERANCE MODE If indoor intake temp – Remote control temp

Page 25 - 10.3.5 Pipe Insulation

31 30 sCompressorOutdoor FanONONOFFOFFONAirflow Direction 12.3.1 Vertical Airflow CoolingOperating Mode1 2

Page 26 - 11. Service Mode

32 Power Button pressed PIPING TEMP.(COOLING) FAN SPEED ( rpm)ONOFFAUTO45 seconds20 ‘Shi20 ‘Fast Cooling Cooling, Soft DryMin.5’ Correc

Page 27

33 seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation mode. From the above judgment, t

Page 28 - 11.3.7 Timer setting button

34 (For YE9MKX,YE12MKX) (YE18MKX) 13.1.4 IPM (Power transistor) Protection Control. 1. DC Peak Cur

Page 29 - 12. Operation Control

35 Indoor suction temperature - indoor piping temperature is below 4℃. Indoor temperature and outdoor temperature is 30±5℃. Remote Control setting 16℃

Page 30 - CS-YE18MKX

36 • This control starts if all conditions continue for 20 minutes: - Operated with Cooling or Soft Dry Mode. - Indoor intake temperature is between 2

Page 31 - 12.3.4 Powerful operation

37 YE9MKX, YE12MKX Indoor piping temp. 60 ℃ 55 ℃ 52 ℃ 49 ℃ 46 ℃ Stop 8Hz/15’’ down 1Hz/15’’ do

Page 32 - 12.3.7 Timer control

38 14. Troubleshooting Guide 14.1 Refrigeration cycle system In order to diagnose malfunctions, make sure that there are no electrical problems befor

Page 33 - 13. Protection control

39 14.1.2 Relationship between the condition of the air conditioner and pressure and electric current Cooling Mode Heating Mode Condition of the

Page 34

4 CAUTION 16. After completion of installation, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant contac

Page 35

40 14.2.3 Error Codes Table

Page 36 - 13.3.1 Indoor Fan Control

41 WARNING 15. Disassembly and Assembly Instructions High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capac

Page 37

42 2.Remove the air filters and then pull out the front grille form the unit body. 1. Separate the drain hose

Page 38 - 14. Troubleshooting Guide

43 1. Release fixing screws on both side, disassembly the fixing board from evaporator on the left side and pull out the whole evaporator.

Page 39 - 14.2.1 About Self Diagnosis

44 16. Exploded View and Replacement Pars List 16.1 Indoor Unit CS-YE9MKX, CS-YE12MKX, CS-YE18MKX

Page 40 - 14.2.3 Error Codes Table

45 No. Parts Name Q'ty CS-YE9MKX CS-YE12MKX CS-YE18MKX RE 1 CHASSIS COMPLETE 1 CWD50C1686 CWD50C1686 CWD50C1686 2 FAN MOTOR 1 CWA921479 CW

Page 41 - WARNING

46 16.2 Outdoor Unit CU-YE9MKX, CU-YE12MKX, CU-YE18MKX

Page 42

47 NO PART NAME&DESCRIPTION Q'TY CU-YE9MKX CU-YE12MKX CU-YE18MKX RE1 CHASSIS ASS'Y 1 CWD52K1262A CWD52K1258A CWD52K1267A 2 FAN M

Page 43

5 2. Specification Indoor CS-YE9MKX CS-YE12MKX Model Outdoor CU-YE9MKX CU-YE12MKX Phase, Hz Single, 50 Single, 50 Power Supply V 230 230 Min Rate

Page 44 - 16.1 Indoor Unit

6 Lo m3/min (ft3/m) 9.10 (321) 10.84 (383) Me m3/min (ft3/m) 11.05(390) 12.23 (432) (HEATING) Hi m3/min (ft3/m) 13.0 (459) 13.9 (491) Hi (Coolin

Page 45

7 Indoor CS-YE18MKX Model Outdoor CU-YE18MKX Phase, Hz Single, 50 Power Supply V 230 Min Rate Max kW 1.00 5.00 5.30 BTU/h 3410 17050 18080 Capacit

Page 46 - 16.2 Outdoor Unit

8 Hi (COOLING) m3/min (ft3/m) 36.0 (1271) Outdoor Airflow Hi (HEATING) m3/min (ft3/m) 37.0 (1307) Control Device Expansion valve Refrigerant

Page 47

9 3. Features • Inverter Technology o Wider output power range o Energy saving o Quick Cooling o More precise temperature control • Long Insta