56
Indoor Unit
Outdoor Unit
Test conditions
1. Cooling: Indoor Dry Bulb Temp. (°C) 27 Outdoor Dry Bulb Temp. (°C) 35
Wet Bulb Temp. (°C) 19 Wet Bulb Temp. (°C) 24
Heating: Indoor Dry Bulb Temp. (°C) 20 Outdoor Dry Bulb Temp. (°C) 7
Wet Bulb Temp. (°C) 12 (MAX) Wet Bulb Temp. (°C) 6
2. Standard piping length: 7.5m (Includes Indoor Unit piping length).
Model
CS-RE9HKE
CU-RE9HKE
CS-RE12HKE
CU-RE12HKE
COOL HEAT COOL HEAT
Single, 230V, 50Hz Single, 230V, 50Hz
Power/Current
[W] 730 820 1010 1120
[A] 3.50 3.90 4.70 5.00
Refrigerant
[k
g
]
R410A
0.78
R410A
0.97
Cooling Capacity
[kW] 2.60 3.50
Heating Capacity
[kW] 3.30 4.25
Noise Level
JIS C 9612
[<70 dB(A)]
[dB(A)]
42 42 42 42
Conditions
1m Distance
Max. cooling/
heating
operation
47 48 48 50
Sound power
level
[dB(A)]
53 53 53 53
60 61 61 63
Air Circulation
[m
3
/min.] 11.6 12.2 11.7 12.4
Product Weight
[k
g
]
8.5 8.5
28 30
Dimensions (H × W × D)
[mm]
280 × 799 × 183 280 × 799 × 183
540 × 780 × 289 540 × 780 × 289
kg
PRODUCT SPECIFICATION PRODUCT SPECIFICATION