Vue de la page 4
OutdoorUnit
5
Anti-reverseProtection
Toprotectthecompressorfromreverse
rotationwhenpoweroffsuddenly.
OverloadProtector
60-secondsTestOperationControl
Oncethecompressorisactivated,itdoesnot
stopfor60seconds.Itstopsimmediatelywith
remotecontrolON/OFFbutton.
Anti-freezingoperationforoutdoorunit(during
HeatingModeOperationonly)
Temperatureofthecondenseristestedbysensor.
DeicingControl
OverloadProtectionControl
Whenthetemperatureofevaporator
reaches51,outdoorfanstops,andwill
restartwhenthetemperatureofevaporator
declinesto49.
Whenthetemperatureofevaporator
reaches65,compressorwillstop.
4-wayValveControl
IftheunitisstoppedduringHeating
Operation,the4-wayvalvewillremainin
heatingmodeoperationfor5minutes.
CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE
CU-UW9GKECU-UW12GKE
The2-stepOverloadProtectoristoprotect
thecompressorwhen
1)Temperatureofcompressorreaches
2)Hightemperatureorcurrententersintothe
compressor