CONNECTIONS
1. Dip Switch Setting
Before connecting this controller, confirm the Dip
Switch Setting if the system setting change is required.
Pulse (VTR): +5V DC approx. 500msec.
Initially, VTR position is selected at the factory.
2. Set switch (SW2) on the board to choose the char-
acter display mode on the monitor.
NOR : White with Black border
REV : Black with White border
Initially, normal (NOR) position is selected at the
factory.
OPC
VTR
REV
NOR
REV
NOR
SW1
SW2
SW5
SW3
SW4
Front
Rear
1. Set switch (SW1) on the board to
choose the alarm reset output sig-
nal as either Open Collector (OPC)
or Pulse (VTR).
Open Collector (OPC) :
16V DC 100mA max.
3. Confirm switches (SW3) on the
board are set to the position as
shown. These switches are used
only for factory test.
4. Confirm switch (SW4) on the
board is set to the "VS" position.
This switch is used only for fac-
tory test.
1234
OFF