-14-
1
M1
SPOT
Controller 1
Operator 1
Priority 1
M2
SPOT
Controller 2
Operator 2
Priority 2
M3
SPOT
Controller 3
Operator 3
Priority 2
Controller
Partitioning
Operator's
Partitioning
Operator's
Priority
2
3
4
5
1
2
3
4
5
4
5
6
7
8
6
7
8
L
CLOSE
OPEN
IRIS
R
UP
DOWN
NEAR
FAR
FOCUS
BUSY
TELE
WIDE
ZOOM
0
987
654
321
ALARM MONITOR CAMERALOCKPOWER PROHIBITED
CAMERA SITE CONTROL
L
CLOSE
OPEN
IRIS
R
UP
DOWN
NEAR
FAR
FOCUS
BUSY
TELE
WIDE
ZOOM
0
987
654
321
ALARM MONITOR CAMERALOCKPOWER PROHIBITED
CAMERA SITE CONTROL
L
CLOSE
OPEN
IRIS
R
UP
DOWN
NEAR
FAR
FOCUS
BUSY
TELE
WIDE
ZOOM
0
987
654
321
ALARM MONITOR CAMERALOCKPOWER PROHIBITED
CAMERA SITE CONTROL
1. In the above system, when Operators 1 and 2 both
select camera 3 simultaneously, the selection of
Operator 1 is allowed because Operator 1 has a
higher priority.
2. Operator 2 cannot select camera 6 because opera-
tor's partitioning limits access to cameras 1 - 5 by
Operator 2.
3. Operator 2 cannot control Monitor 3 because con-
troller partitioning prevents access to Monitor 3 by
Operator 2.
15. Synchronizing the Sequence with
External Timing
The camera switching interval (Sequence Dwell Time)
can be synchronized with the time lapse mode set in the
associated Time Lapse VTR.
Select the On or Off mode to meet each monitor’s
requirements on the EXT TIMING setup table.
Caution: Set the interval time for the external timing sig-
nal of the external equipment to one (1) second or
more.
If the interval is set to less than one (1) second, the
system will not work properly.
16. RS-485 Site Communication
The parameters for communication with the Camera Site
can be set on the RS485 CAM COM. setup table.
Usually, the Baud Rate is set to 9,600 bps, with a Wait
Time of 100 ms.
(The WV-RM70 Camera Controller or a modem may be
required in the system.)
Note: Be sure to select the correct Baud Rate when
using a modem.
17. Clock
On-screen clock display is available.
The date and time can be set on the CLOCK SET setup
table.
18. RS-232C Port
This port is used for connecting with a Personal
Computer. The memory of the WJ-SX350 Matrix
Switcher can be loaded or saved.
Also, a Personal Computer can be substituted for the
Switcher to control the system.
Note: For using a Personal Computer, you will need