Panasonic WJMP204 Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Caméras de sécurité Panasonic WJMP204. Panasonic WJMP204 Operating Instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - WJ-MP204

Before attempting to connect or operate this product,please read these instructions carefully and save this manual for future use.Model No. WJ-MP204Da

Page 2 - ENGLISH VERSION

10Address setting varies from one communication mode to another.The setting should be made by qualified service personnel or system installers. Panas

Page 3 - CONTENTS

11The Setup menu consists of two main menus: one for communication setup for connection to cameras and the system con-troller WV-CU360, and the other

Page 4 - FEATURES

12WJ-MP204 SETUP MENU X.XX COMMUNICATION SYSTEM Displaying the Setup Menu forPanasonic Security Data Mode1. Check that the cameras and peripheral

Page 5 - COMMUNICATION MODE

13 COMMUNICATION UNIT ADDRESS 1 BAUD RATE 9600 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF(6) Wait Time Settin

Page 6 - ■ Front View

14OFF by pressing button 3 (–) or button 4 (+).The initial factory setting is ON.• Terminal Alarm Setting1. Display the SYSTEM menu.2. Move the cursor

Page 7 - ■ Rear View

15(2) Comp/VD2/Data Setting• Camera Input Setting1. Display the SYSTEM menu.2. Move the cursor to CAMERA IN by pressing button 1(C) or button 2 (D), p

Page 8 - SETUP PROCEDURE

16WJ-MP204 SETUP MENU X.XX COMMUNICATION SYSTEM Displaying the Setup Menu ofCamera Communication Mode1. Check that the cameras and peripherals ar

Page 9 - DIP SWITCH SETTING

17(4) Parity Check Setting1. Display the COMMUNICATION menu.2. Move the cursor to PARITY CHECK by pressing button1 (C) or button 2 (D), then select th

Page 10 - SETTING ADDRESSES

18 System Setup for CameraCommunication Mode1. Display the Setup menu.2. Move the cursor to SYSTEM by pressing button 1 (C)or button 2 (D), then pres

Page 11 - (see page 16 - 19)

19ON: Multiplex sync signals (VD2) are generated by syn-chronizing with the signals sent to the VS/VD INconnector. If there is no input signal, the in

Page 12 - ■ Communication Setup of

2ENGLISH VERSIONThe serial number of this product may be found on the bot-tom of the unit.You should note the serial number of this unit in the spacep

Page 13 - Security Data Mode

20Joint metalRemove 2 screws from the rear beforehand.Rack mountingbracket (small)Rack mountingbracket (small) Mount screw Binding head (M3x8)Mount sc

Page 14 - (1) Alarm Mode Setting

21 BASIC SYSTEM CONNECTION (Panasonic Security Data Mode)The Data Multiplex Unit WJ-MP204 may be connected to cameras, video monitors, and system con

Page 15 - (4) Camera Config

22● Connecting Two or More Data Multiplex Units to System Controller WV-CU360(Panasonic Secuarity Data Mode)SD RDIN INCAMERA RS485ABABGVS/VDSPOT DATAA

Page 16 - ■ Communication Setup for

23● Connecting Two or More Data Multiplex Units to Matrix Switcher WJ-SX350 (CameraCommunication Mode)TRIN INCAMERA RS485ABABGVS/VDSPOT DATAALARM / RE

Page 17

24Pin #123456 (1CH)For AlarmInputAlarm OutputAlarm Recover InputAlarm Reset OutputSpot SW InputSpot SW OutputAlarm Input 1 Alarm Output 1(Camera Site

Page 18 - Communication Mode

2512340/5VO.C4321ON OFFSW702SW704FixedOnly displays the Setup menu to SPOT OUT.Displays the Setup menu to CAMERA OUT (1 - 4) and SPOT OUT.ONSW7021 OFF

Page 19 - (5) Terminal

26 Connection to WV-CU360● Basic ConnectionConnect the DATA port on the Data Multiplex Unit to one of the DATA port on the System Controller with the

Page 20 - INSTALLATION

27 Controlling the CameraFunctions with the DataMultiplex Unit WJ-MP204Before starting operation, loosen the screw on the frontcover with a screwdriv

Page 21 - SIGNAL GND

28ALARM CONTROL FUNCTIONSALARM 001 Alarm InputThe Data Multiplex Unit processes the following alarms.(As to setting, see page 14, 18 and 19.)• Camera

Page 22 - Video signal

29SPECIFICATIONSSTANDARD ACCESSORYPower Source : 220 - 240 V AC 50 HzPower Consumption : 7 WCamera Input : 1 V[p-p]/75 Ω x 4Spot Input : 1 V[p-p]/75 Ω

Page 23 - Communication Mode)

3CONTENTSPREFACE ...

Page 24 - CN 702 ALM OUT

Function30CameraSelectionAlarm ResetAlarm SuspendWJ-MP2044321RESETALARMSETSUSPENDALARMWV-CU360Alarm SuspendResetSETSUSPENDALARMAPPENDIX Operation of

Page 25 - ■ RS485 Terminal

N1299-1030 YWV8QA5360BN Printed in JapanN 19 Gedruckt in JapanImprimé au JaponImpreso en Japón2000 © Matsushita Communication Industrial Co., Ltd. Al

Page 26 - Controller end

4PREFACEFEATURESThe WJ-MP204 Data Multiplex Unit enables you to remotecontrol multiple surveillance cameras, check alarm set-tings, operate the camera

Page 27 - OPERATING PROCEDURES

5PRECAUTIONS• Refer all work related to the installation of thisproduct to qualified service personnel or systeminstallers.• Do not block the ventilat

Page 28 - ALARM CONTROL FUNCTIONS

6MAJOR OPERATING CONTOROLS AND THEIR FUNCTIONSq Power Switch (POWER ON/OFF)Press once to turn on the Data Multiplex Unit. The switch remains down (;)

Page 29 - ALL RESET

7 Rear Viewo Camera Input Connectors 1-4 (CAMERA IN 1, 2, 3, 4)These connectors accept the composite video signalfrom the camera.!0 Camera Output Con

Page 30 - APPENDIX

8Follow the procedures below for setup.1. Press the Power Switch back to the OFF position.Check that the Power Switch LED is off.SETUP PROCEDURE2. Set

Page 31 - Impreso en Japón

9Before connecting the Data Multiplex Unit, check how theDIP switches are set on the rear panel in cases where thesystem setup must be changed. Setti

Commentaires sur ces manuels

Pas de commentaire