About the error log
The following are the descriptions about the contents of the error log and the network log.
• "x"indicatestheextensionunitnumber.
• "y"indicatestheHDDunitnumber.
Content Error log Network Log Display on
Monitor2
Output from the
connector at
the rear panel
Outage detection POWER LOSS POWER Error + Outage
processing end*
Recover from a power out-
age
POWER RECOVERED
Alteration detection ALTERED **CH ALT–*
(*: camera ch)
Error
No response from an
address of Panasonic
alarm protocol
PANASONIC_ALM_RES_ERR
Failed to resolve a address
of Panasonic alarm proto-
col from DNS
PANASONIC_ALM_ADD_ERR
Other error for an address
of Panasonic alarm proto-
col
PANASONIC_ALM_OTHER_
ERR
Parameter initialization
error
FAN warning Recorder: MAIN FANy ERROR
Extension unit: EXTx FANy
ERROR
FAN Error
Thermal error warning Recorder: MAIN THERMAL
ERROR
Extension unit: EXTx THERMAL
ERROR
THERMAL Error
Reboot by the system
error
SYSTEM REBOOT
HDD remove error (proper-
ly recognized HDD was
removed without opera-
tions on the front panel)
Recorder: MAIN-y SWAP
WARNING
Extension unit: EXTx-y SWAP
WARNING
SWAP_ERR HDD error
HDD write error •PerHDD(Inthesinglemode)
Recorder: MAIN-y WRITE
ERROR
Extension unit: EXTx-y WRITE
ERROR
•Perunit(intheRAID5or
RAID 6 mode)
Recorder: MAIN WRITE ERROR
Extension unit: EXTx WRITE
ERROR
HDD read error •PerHDD(Inthesinglemode)
Recorder: MAIN-y READ
ERROR
Extension unit: EXTx-y READ
ERROR
•Perunit(intheRAID5or
RAID 6 mode)
Recorder: MAIN READ ERROR
Extension unit: EXTx READ
ERROR