Indoor Pan/Tilt Head AW-PH400
13 (E)
Installation (Be sure to ask your dealer to install the unit.)
$ Changing the mounting position of the pedestal connector panel
If necessary, the position at which the pedestal connector panel is mounted can be moved to the opposite side of the unit.
1 Remove the four screws for the pedestal connector panel, and pull out the pedestal connector panel.
2 Disconnect all six connectors of the PCB at the back of the pedestal connector panel.
3 Remove the four screws for the side blank panel, and remove the side blank panel.
4 Move the pedestal connector panel to the opposite side, and re-connect the connectors of the PCB as before.
5 Screw down the pedestal connector panel and side blank panel.
Neither the mounting position nor the mounting direction of the rotary head connector panel can be changed.
Pedestal connector panel
Rotary head connector panel
Side blank panel
(opposite side)